    Salt Spray & Cyclic Corrosion Testing

    Increase font size  Decrease font size Date:2013-07-08  Views:3184
    Core Tip:Salt Spray Cyclic Corrosion TestingThe purpose of this document is to explain the fundamental differences between these

    Salt Spray & Cyclic Corrosion Testing

    The purpose of this document is to explain the fundamental differences between these two popular forms of corrosion test.

    Salt Spray Test

    Salt is one of the most commonly occurring compounds in the world. It is found in the oceans, in the atmosphere, on ground surfaces and in lakes and rivers.

    The salt spray test is one of the most wide-spread and long established corrosion tests:

    • In 1914 a Mr J. A. Capp proposed the use of neutral salt spray for the corrosion evaluation of protective coatings on ferrous surfaces.
    • ASTM B117 was the first internationally recognised salt spray standard, originally published in 1939. This is still the most popular test world-wide today and has often been used as the basis for other ‘national’ or ‘industry specific’ salt spray test standards.

    So salt spray testing has a long history, with a lot of test data available relating to the expected corrosion resistance of a wide variety of materials and surface coatings.

    Such salt spray tests generally require the following test conditions to be created:

    1. A 5% by weight salt water solution is atomised by compressed air into a spray (also known as a ‘fog’ or ‘mist’) which is directed into an enclosed test chamber, containing the samples to be tested. The samples are located beneath the atomised salt spray and therefore not directly impinged upon by it.
    2. The salt spray so created ‘falls-out’ on to the samples under test at a rate of 1.0 to 2.0ml/80cm²/hour. Generally, and unless otherwise stated, the pH of this fall-out shall be neutral and controlled to between pH6.5 to 7.2.
    3. The salt spray atomisation is continuous for the duration of the test. The test duration varies according to the type of test sample and its intended application, but is generally given in multiples of 24 hours.
    4. Generally, and unless otherwise stated, the test chamber temperature shall be controlled at +35C, and the humidity shall be maintained at 95-100%RH. These conditions are maintained constantly for the duration of the test.

    Other parameters are also controlled, such as the purity of the salt and water to be used to make up the test solution, and the position/orientation of the test samples inside the chamber. The purpose being to control all test variables to the extent that only the corrosion resistance of the samples under test may vary.

    Because the test conditions specified for salt spray testing are not typical of a naturally occurring environment, this type of test can not be used as a reliable means of predicting the ‘real world’ service life expectancy for the samples under test. However, it is useful for conducting comparative testing, where the actual results obtained are compared with the results expected (perhaps from previous tests). Its main application is therefore in the role of quality auditing. So, for example, a spray test can be used to ‘police’ a production process and forewarn of potential manufacturing problems or defects, which might affect corrosion resistance.

    Despite its lack of correlation to ‘real world’ corrosive conditions, the salt spray test remains popular, in a wide range of industries, as an effective means of quality auditing relative corrosion resistance, for a variety of surface coatings and/or the processes by which they are applied.

    Cyclic Corrosion Test (also known as CCT)

    It is generally accepted that CCT, as we know it today, originated in the automotive industry during the 1980’s. Although there had been earlier experiments with ‘cyclic derivatives’ of the traditional salt spray test, none of these were widely adopted.

    The reason CCT was developed was to address the fundamental weakness of the traditional salt spray test, which is that it can not be used as a reliable means of predicting the ‘real world’ service life expectancy for materials and products. This was of particular concern in the automotive industry.

    With ever increasing consumer pressure for improved vehicle corrosion resistance and a few ‘high profile’ corrosion failures amongst some vehicle manufactures – with disastrous commercial consequences, the automotive industry recognised the need for a different type of corrosion test. One that simulated the types of conditions a vehicle might encounter naturally, but recreate and accelerate these conditions, with good repeatability, within the convenience of the laboratory.

    Taking results gathered largely from ‘real world’ exposure sites, automotive companies, led originally by the Japanese auto industry, developed their own Cyclic Corrosion Tests. These have evolved in different ways for different vehicle manufacturers, and such tests still remain largely industry specific, with no truly international CCT standard. However, they all generally require most of the following conditions to be created, in a repeating sequence or ‘cycle’, though not necessarily in the following order:

    1. A salt spray ‘pollution’ phase. This may be similar to the traditional salt spray test, although in some cases direct impingement by the salt solution on the test samples, or even complete immersion in salt water, is required. However, this ‘pollution’ phase is generally shorter in duration than a traditional salt spray test.
    2. An air drying phase. Depending on the test, this may be conducted at ambient temperature, or at an elevated temperature, with or without control over the relative humidity and usually by introducing a continuous supply of relatively fresh air around the test samples at the same time. It is generally required that the samples under test should be visibly ‘dry’ at the end of this test phase.
    3. A condensation humidity ‘wetting’ phase. This is usually conducted at an elevated temperature and generally a high humidity of 95-100%RH. The purpose of this phase is to promote the formation of condensation on the surfaces of the samples under test.
    4. A controlled humidity/humidity cycling phase. This requires the tests samples to be exposed to a controlled temperature and controlled humidity climate, which can either be constant or cycling between different levels.

    The above list is not exhaustive, since some automotive companies may also require other climates to be created in sequence as well, for example; sub-zero refrigeration, but it does list the most common requirements.

    Because the test conditions specified for CCT simulate and accelerate naturally occurring conditions, this type of test can be used as a means of predicting the ‘real world’ service life expectancy for the samples under test. So, although a CCT can be useful for conducting comparative tests, like a traditional salt spray test, it is also possible to use a CCT chamber as a research and development tool in the development of improved corrosion resistant materials and surface coatings.

    This flexibility is starting to make the CCT an increasingly popular alternative to traditional salt spray testing, particularly within the automotive industry where it originated, but also in other industries as well.

     
     
    [ NewsSearch ]  [ ]  [ Tell a friend ]  [ Print this article ]  [ Close window ]

     

     
    Recommended Graphic
    Recommend News
    Click Ranking
     
    Contact QQ:1006931501*蘇ICP備11049648號-15蘇州亞諾天下儀器有限公司 版權所有
    +86 18915433994
    Buy pulling machine, preferred Coors brand! Contact Us | YANUO Group | Back Home【Service Hotline:+86 512 68559199】
    主站蜘蛛池模板: 国产成人自拍小视频在线| 级毛片无码av| 日韩av一区二区毛片| 国产精品国产三级国产an| 久久99一本色道亚洲精品| 无码国产精品一区二区免费式芒果| 金沙县| 亚洲精品亚洲人成在线播放| 国产免费三级三级三级| 日韩不卡无码三区| 滦平县| 崇明县| 四川省| 久久99久久99精品观看| 最新在线观看精品国产福利片| 在线一区二区三区人妻| japanese色国产在线看视频| 中文字幕少妇人妻视频| 海阳市| 景泰县| 日本精品人妻在线观看| 午夜一区二区三区在线视频| 久久久诱惑一区二区三区| 亚洲av乱码国产精品色| 亚洲中文字幕永久网站| 亚洲嫩模尤物大尺度高清人体| 亚洲国产精品久久久性色av| 最新国产精品精品视频 | 罗江县| 沙雅县| 安吉县| 亚州AV成人无码久久精品| 巴林右旗| 抚宁县| 东京热加勒比日韩精品| 精品一区二区三区在线视频观看| 99久久精品国产片| 日本啪啪一区二区三区| 超碰在线公开中文字幕| 亚洲精品成人av一区二区| 亚洲视频一区二区三区在线观看 |